Revision History for MECASeismic Software

1.0.2.0 08/23/08 First official release of software
1.0.2.1 10/16/08 Correct Eqn 12-8.5 from 0.1 to 0.01
    Minor correction in output formatting
    Correct project info to be single line inputs (aka Joe Mama).
    Add Override for Seis Des Cat. to help in places like Hawaii
    Correct load combination that was being displayed for Equiv lateral Force ASD
1.0.2.2 10/19/08 Correct Cmax calculation for Buildings
1.0.2.3 11/02/08 Corrected bug that had bldg limits flipped for sub-class A13
1.0.2.4 11/26/08 Corrected bug with Eqn 12.8-5, the value was .1 instead of .01
1.0.2.5 02/11/09 Corrected bug with NonBuilding that said struc exceeded limit, even though it didn't
1.0.2.6 12/15/09 Modify to be compatible with 64 bit operating system
1.0.2.7 02/15/10 Approx period calc limited to 3 shear walls, and this was increased
1.0.2.8 02/24/10 Correct weights for buildings greater than 10 stories
1.0.2.9 08/27/10 Correct case for Non-Structural, N, Subcase N6 that wasn't working