Version |
Date Rev. |
Description of Revisions |
| |
|
|
| 2.0.0.6 |
01/29/08 |
Corrected bug that kept changing building width back to 1 ft |
| 2.0.0.7 |
01/30/08 |
Corrected bug when OH = 0 the zones for C&C were erased |
| 2.0.0.8 |
02/25/08 |
Corrected Solid Sign Text error for Case C when S-dim was
not an integer. Resolved potential load error for other structure |
| |
|
Components and Cladding calculation error only if you switch
from an OPEN Building to an Enclosed or Partially Enclosed building. |
| |
|
Roof type changes to 'Gable' style roof automatically when
switching from Open Building roof type (Troughed or Pitched) to an
enclosed building. |
| |
|
'Override mean height of roof & 'Alt Design Wind
Pressure' option now allows the user to save it' |
| |
|
Error Checking now ensures the user doesn't enter a value
other than 5 ft (1.5m) or 10 ft (3.0m) for the elevation increment |
| |
|
Roof Area calculation has been corrected. In some
cases it was wrong. |
| 2.0.0.9 |
03/03/08 |
Corrected Solid Sign Text error for Case C when S-dim was
not an integer. Resolved potential load error for other structure |
| 2.0.1.0 |
03/09/08 |
Corrected bug. If bldg ht>60 ft and height was
changed, the C&C Elevation was not changed |
| |
|
If Ht was entered by using override option, then the
Alternative Method option was not being enabled when applicable |
| |
|
When user clicked from Bldg tab to Analysis, the C&C
data sometimes lost. It worked when 'Next' selected. Bug
fixed. |
| |
|
Reworked the Parapet C&C calc to be more comprehensive
and complete. Revised notation to be clearer. |
| |
|
C&C for Ht>60 ft the Delete Line option didn't delete
Elev. and Populate did not add Elev data. |
| |
|
Add 'Security' option to top tool bar and simplified
Software Activation Menu. |
| |
|
Add to floating network option to enter Email and Computer
ID to help MECA identify who has license locked up. |
| 2.0.1.1 |
04/12/08 |
Fixed so Domed Roof doesn't display RHt and EHt |
| |
|
Enabled use of Elevation increments of any value |
| |
|
Open Bldg can't enter slope of zero. |
| |
|
Release license when program uninstalled |
| 2.0.1.2 |
04/21/08 |
Updated purchase options for upgraded to software
maintenance |
| 2.0.1.3 |
05/23/08 |
Corrected bug that changes computer id and causes users copy
to be deactivated. |
| 2.0.1.4 |
05/31/08 |
C&C sometimes wouldn't save, and added explanation for
span and length on C&C |
| 2.0.1.5 |
08/01/08 |
Made adjustment to allow program to run on Windows Vista
64bit |
| 2.0.1.6 |
08/20/08 |
Corrections to security so that email and description values
entered are retained |
| |
|
Add ability to enter a base elevation for the structure, so
that the Kz values are modified accordingly |
| 2.0.1.7 |
09/18/08 |
Expand Chimney option to allow more input and control.
Also add Para 6.5.15.1 for factor for rooftop structure |
| 2.0.1.8 |
09/22/08 |
Option of 02 code disappeared in last version, so added it
back to the menu. |
| 2.0.1.9 |
09/24/08 |
Corrections to new Chimney Calculation procedure |
| 2.0.2.0 |
09/30/08 |
Revise way in which output screens are loaded to try to fix
'clipboard' error |
| 2.0.2.1 |
10/13/08 |
Correct working for Parapet C&C Case B. Negative
press applied to FRONT of face |
| |
|
Correct bug where clicking tabs didn't always retain values
like clicking 'next' and 'back' |
| 2.0.2.2 |
10/14/08 |
Correct bug that disabled elevation increment option |
| 2.0.2.3 |
10/26/08 |
Corrected bug that displayed detailed results when
simplified selected |
| |
|
Corrected bug to make sure that a code is selected |
| 2.0.2.4 |
11/10/08 |
Corrected problem with simplified analysis. Roof area
for gabled roof 1/2 of actual value, and corrected problems with Chimney
type not holding values. |
| 2.0.2.5 |
01/21/09 |
Important!! Correct error that produced wrong Bldg
Moment by a factor of approx 1/2 |
| 2.0.2.6 |
02/11/09 |
Increase size of array so that C&C can have more than
100 lines (200 max) |
| 2.0.2.7 |
02/22/09 |
Correct bug that resets C&C elev's to Ridge Ht (applies
to bldg > 60 ft) |
| 2.0.2.8 |
04/07/09 |
There was a bug for C&C on Walls zones 4 & 5.
Program gave 10% reduction for <=7 Deg. should be <=10 Deg |
| 2.0.2.9 |
11/18/09 |
Corrected bug with Open structures, the C&C was pulling
from Fig 6-11 by mistake |
| 2.0.3.0 |
12/12/09 |
Corrected bug that was giving all C&C pressures as 10
psf for enclosed buildings |
| 2.0.3.1 |
01/11/10 |
Revision History wasn't displaying |
| |
|
***MAJOR UPDATES*** |
| 2.1.0.0 |
04/02/11 |
Release New Version to Beta Testers. New version
incorporates the following: |
| |
|
ASCE 7-10, new code with many changes |
| |
|
Methods to estimate natural frequency of flexible structures |
| |
|
Removed 'Summarized' output option because it was
problematic |
| |
|
Many other bug fixes and clean-up |
| 2.1.0.1 |
04/18/11 |
Various bug fixes for new version |
| 2.1.0.2 |
05/15/11 |
Minor bug fixes found during checking |
| 2.1.0.3 |
06/02/11 |
Fix bug that caused NaN output, because it treated every
struc as flexible |
| 2.1.0.4 |
6/22/11 |
Fix bug for Sawtooth that calculates x:12 slope wrong.
Added back total shear |
| |
|
and moment, but added note that roof and end gable not
considered. Remove |
| |
|
zone 3 for sawtooth, only 3A, 3B, 3C and 3D should be
considered. Fixed |
| |
|
problem with opening existing files and not bringing in all
data |
| 2.1.0.5 |
6/23/11 |
Fix bug where C&C not displaying correctly for Open
building |