Articles

Wind on Rooftop Structures and Equipment

Wind on Rooftop Structures and Equipment

ASCE 7 has a method for calculating wind loads on rooftop Structures and equipment for buildings, and this article will describe that method.  Fortunately, the method is relatively straight forward, not too complicated, and is covered in ASCE 7-16 Section 29.4.1What...

read more
Components and Cladding Example

Components and Cladding Example

This article provides a Components and Cladding (C&C) example calculation for a typical building structure.  We will first perform the calculations manually, and then show how the same calculations can be performed much easier using the MecaWind software. What is...

read more
Fastest-Mile Wind Speed

Fastest-Mile Wind Speed

Many times we have the difficult task of analyzing a structure that was designed long ago.  In such cases, you may find that the wind speed  used may appear significantly lower than the wind speed you would expect for that location using today's standards.  In these...

read more
Wind Wizard

Wind Wizard

MecaWind has many features and options within the software, which can be both a blessing and a curse.  It gives the user greater control over the results they obtain, but for the novice user it can be overwhelming to understand what is being requested with each...

read more
How to Find Wind Pressure on Solar Panels

How to Find Wind Pressure on Solar Panels

In this article we will investigate the procedure for calculating the design wind pressure on rooftop solar panels per ASCE 7-16 design code. I feel like the best way to describe this procedure is by working through an example, and that's just what we will do. For...

read more
Base Reactions in MecaWind

Base Reactions in MecaWind

There can be confusion from users on how to read and interpret the MecaWind Base Reactions that are provided by the MecaWind software program.   There is a lot of data presented, and it can become overwhelming.  This article is intended to help explain how MecaWind...

read more
ASCE 7 Flexible Gust Factor

ASCE 7 Flexible Gust Factor

When I was a new Engineer my boss had his stack design questioned by a client.  My boss responded "Sir, I will serve you tea on the downwind side of that stack on the windiest day of the year."   That line (and disturbing image) has never left my mind.  Designing tall...

read more
One Click Components & Cladding

One Click Components & Cladding

Would you like to be able to calculate all of your Components & Cladding (C&C) values with one Click?  In this article that's what we are going to show you.  Component and Cladding Summary: The normal way of analyzing C&C in MecaWind is to enter each...

read more
I Feel the Need to Change Wind Speed

I Feel the Need to Change Wind Speed

It was Tom Cruise in "Top Gun" who once said, "I feel the need, the need for speed".  I sometimes wonder if Tom Cruise is on the ASCE 7 committee, because it feels like they have the need to change the wind speed basis with every new release of ASCE 7.  I'm not...

read more

Subscribe

Enter information below to subscribe to our newsletters

Success!

You will receive an email shortly to select your topics of interest.